Key Takeaways on How Changes in the New NFPA Standards for Turnout Gear and SCBA Will Affect the Fire Service

4 Min Read | Mar 19, 2024

Reading Time: 4 minutes From the specifications for soft goods to ratings for electronics in explosive environments, the upcoming consolidation of standards will offer greater protection for firefighters

March 19, 2024 by Melina Magino

Reading Time: 4 minutes

Laura Neitzel | FireRescue1 | BrandFocus Staff

Every five years, the National Fire Protection Association (NFPA) reviews and updates standards to keep abreast of scientific advances, new product capabilities and rigorous testing improvements, all to address firefighter health and safety.

NFPA is currently in the process of consolidating NFPA 1971, covering turnout gear, and NFPA 1981, for self-contained breathing apparatus (SBCA), into one comprehensive standard – NFPA 1970 – that also incorporates station/work uniforms (NFPA 1975) and personal alert safety systems (PASS) (NFPA 1982).

Recently, MSA Safety hosted a webinar exploring the finer details of the consolidation as it relates to PPE and SCBA. Leading the discussion were Jeff Stull, an expert in PPE design evaluation and selection and a member of several NFPA technical committees, and Matt Cox, battalion chief for Fairfax County Fire and Rescue in Virginia.

The discussion included how the NFPA process works to address firefighter protection needs, the significant changes that will be applied in NFPA 1971 and NFPA 1981, and overall implications of the new standards for the fire service.

Following are key takeaways from this webinar, which you can view on demand here.

Purpose. The consolidation of standards associated with structural firefighting – protective clothing (including turnout gear), work uniforms, SCBA and PASS – will become NFPA 1970. The hope is the consolidation will make the standards easier and create a synergy where similar requirements are grouped together, ultimately for the benefit of end users.

Effective dates. The new NFPA 1970 standard is expected to be promulgated in August 2024. Any new products certified after this date will need to meet these new requirements. Products that meet the older edition will have an 18-month grace period to continue to be sold until manufacturers bring their products up to the new standard.

New requirements for hoods. All structural firefighting hoods will need to have particulate blocking capabilities under the new standard. This will increase protection against particles and chemicals reaching the skin.

“Under the new standard, all structural firefighting hoods will have to have particulate blocking capabilities. So, any of those departments or firefighters that are now using the regular knit hoods … that’s going to be a very noticeable difference.”

Jeff Stull

The new hoods will have a slight impact on breathability and some manufacturers will have to introduce multiple sizes. Some existing products may not meet the new requirements, and the hoods will likely become more expensive due to the additional capabilities.

Increasing protection in one area may come at the expense of another, such as comfort and breathability.

PFAS-free labeling. New standards will require gear to be labeled as PFAS-free. This will involve testing and verification processes to ensure no PFAS has been incorporated into the product. Many states already require manufacturers to disclose if they have PFAS in their product and have banned firefighting foams. The change will facilitate standardizing and demonstrating these claims. Challenges remain in achieving PFAS-free labeling and related standards, with some areas achieved and others still progressing.

“We know this is an evolving topic where we’re trying to get the metrics correct, we’re trying to make sure that claims are accurate, and we want to provide the fire service with the opportunity to choose that gear if it so exists. This is an area that the standard is trying to facilitate … making sure that these claims are standardized and demonstrated adequately.”

Jeff Stull

Rating electronics for explosive environments. Given that more functions for SCBA are electronic in nature ­– such as heads-up displays, accountability software, and integrated thermal imaging and communications – intrinsic safety is a key concern as firefighters navigate the “Immediately Dangerous to Life or Health” (IDLH) environment. NFPA 1970 will include new criteria for rating devices for explosive environments.

“It’s paramount we understand how our equipment will react with the IDLH environment.”

Matt Cox

End-of-service time indicator. One significant change is the modification of the end-of-service time indicator (EOSTI) for SCBA. The new rule aims to divide the allowable breathing air into three increments: one third for work completion, one third for structure exit and one third as an emergency reserve.

“The standard may affect the time you spend in a structure fire. Understanding how far and how long you and your crew may operate in a structure will allow a proper risk assessment by unit officers and command.”

Matt Cox

Visual alerting for wireless interfaces. Additionally, given the increasing complexity of modern connectivity and critical role communication plays in firefighter safety, NFPA 1970 will also establish criteria for wireless interfaces from SCBA to other devices. This will include the requirement of a HUD visual alert to indicate connection of devices.

PASS device alarm tone. Similarly, the standard incorporates a new universal PASS tone to aid audible detection by the human ear.

Universal Emergency Breathing Safety System. The Universal Emergency Breathing Safety System (UEBSS) supports a buddy breathing operation between two users with compatible SCBA. The universal system will allow buddy breathing regardless of the vendor, says Cox.

Removable soft goods. Because of the importance of cancer-prevention measures, the updated NFPA standards will likely require manufacturers to make it easier to remove soft goods in SCBA so these items can be separately cleaned.

Gross decontamination. It’s a challenge to get firefighters to comply with gross decontamination procedures, says Cox. Requirements of the new standard will facilitate gross decontamination. It will also govern details like second stage regulator retention and removal.

“This seems self-explanatory, but it’s a part of our modern day SCBA. And NFPA has added the text to the standard to ensure compliance. This is an example of the manufacturer staying ahead of the industry and ensuring firefighter safety is priority number one.”

Matt Cox

While the new NFPA 1970 consolidation remains in development, it is expected to offer forward progress that makes it easier for manufacturers and firefighters to adhere to specifications and procedures that enhance the health and safety of firefighters on and off the fireground.

Visit MSA Safety for more information on fire service solutions.

This article reprinted with permission of FireRescue1.

Recommended for You

PPE

Why It’s Crucial that PPE Fits Properly

August 26, 2024
4 Min Read
Education

Tips on Selecting Turnout Gear that Meets the Needs of Your Department

September 30, 2024
< 1 Minute Read
Standards

Webinar – The Final NFPA 1970: Key Protections and Implications for Firefighter Safety

October 7, 2024
2 Min Read
Standards

Expected Changes for the Upcoming Consolidated NFPA 1850 Standard

December 6, 2024
8 Min Read
Share:

Footer

MSA MISSION: That men and women may work in safety and that they, their families, and their communities may live in health throughout the world.

Visit Our Sites

  • MSAFIRE.COM
  • Globe
MSA Fire on Facebook   MSA on X   MSA Fire on Instagram   MSA on LinkedIn   MSA on YouTube  

Contact

  • blog@msasafety.com
  • 1-877-672-FIRE (3473)
  • View All Contact Info
  • Subscribe

Other MSA Blogs

  • Industrial – Spotlight on Safety
  • FieldServer – The Safety Connection

© 2024 MSA. All rights reserved.

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept Read More
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the ...
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Non-necessary
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
SAVE & ACCEPT